Slide INJEX POSITIVE PRESSURE RESPIRATOR View more Enjoy the fresh air and protect the health of doctors and nurses

The product draws outside air into the respirator through a fan, goes through a pre-filter, UVA LED and main filter to remove toxic gases and particles in the air, and finally clean air is expelled through the air.

Product
structure

Respirator

size:φ 101mm×191mm
(diameter×height)

Waist bag

Polyester+PVC

Mask

Silikonkautschuk, E n g i –
n e r i n g p l a s t i c s
P o l y c a r b o n a t e
p i p e fi t i n g s
12 Monate Service Leben

Breathing tube

φ 2 2 m m h o s e, O n e
Ende ist verbunden mit
t h e m a s k C o n e c t
das andere Ende zum
Respirtor

Produkt
overview

① Connect one end of the breathing tube to the air outlet of the breathing tube
Host and the other end to the mask air inlet.
② Attach the hip bag to the hip belt and tie it at the waist.
③ Start the respirator, wear a mask, set the gear and place it in the
Bum bag.

Functional
wise

The product sucks outside air through a fan into the respirator, flows through a pre-filter, a UVA LED and a main filter in turn remove toxic gases and particles in the air and finally is clean air
sent out through the air outlet.

Filter
change

The pre-filter LED lights up and indicates that a new filter is required
Place the pre-filter. The user can buy a new one
Pre-filter to replace. Unscrew the base counterclockwise.
Take out the pre-filter and replace it with a new one. After the replacement is complete, press the reset button, the LED indicator will go out, and the usage time counter will reset again.
Then release the reset button and continue normal operation.

Main
filter

The main filter LED lights up, indicating that the main filter needs to be replaced. The user can –
Chase a new main filter to replace it. Unscrew the top cover, take out the main filter and reinsert it with a new one. After the exchange is complete,
Press the reset button, the replacement main filter, the LED light goes out and the timer for use goes out again to be reset, then release the reset button and continue normal operation.

Application
command

The product is suitable for medical personnel to wear during surgery and to provide users with fresh and clean air and to prevent the influence of pathogenic microorganisms, liquids, and particles.

Produkt
Parameters

venti

Four-speed air
volume adjustment

60SLM
140SLM
210SLM
280SLM
AIR FLOW
(SLM:standard litre per
minute)

BATTERY

Battery

battery capacity:
3000mAH,12V,36WH
Battery runtime:
60SLM>9h
140SLM>8h
210SLM>6h
280SLM>4h
Battery charging
time: fully charged
2H,charged to 80%
capacity 1h

LIGHT

UVC-LED

Peak wavelength:
270-285nm
life span test:≥
10000h
E. coli 8099 killing
rate:99.999%
Staphylococcus
aureus kill rate:
99.999%

SHOWER

Filter

ULPA Filter;
Low pressure drop, highdust
collection efficiency;
Excellent chemical resistance;
Excellent resistance to
acids (such as hydrofluoricacid),
alkalis and organicsolvents;
Excellent moisture resistance;
Excellent water resistance;
Replaceable;

Product
Specifications

Pre-filter

Eliminate large particles and protect the main filter
① waterproof
② Little pressure drop
③ Interchangeable

Mainfilter

ULPA-Filter
① Low pressure drop, high dust collection efficiency
② Excellent moisture resistance
③ Excellent water resistance
④ Interchangeable

Battery

Power indicator 1 LED (Yellow)) Battery low, red light ;
Fan speed display 3 LED (Green)) Fan speed display ;
Pre-filter light 1 LED (Red)) Indicates that the pre-filter
needs to be replaced ;
Main filter light 1 LED (Red)) Indicates that the main filter
needs to be replaced ;

Mainbutton

2-in-1 button that is used as the power button and fan speed button
(Press for 5 seconds to turn on, 5 seconds to turn on
turn off)
Operating temperature -10 ~ ~ 50 ℃, humidity 5% ~ 95%